200W SMPS

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2017-12-28 00:25
Browse the number: 96
inquiry
Company Profile
 
 
Product details


 


Block diagram


Output berating


Static characteristics


Overall dimension


1.Low price and high reliability

2.105 output capacitor

3.AC input power suitable for the world

4.High efficiency and low operation temperature

5.Soft-start current can reduce the AC input impact effectively

6.With short-circuit and overload protection

7.light weight

8.100% full-load burning test

9.Installed with EMI filter, minimum wave


 


Model


Specification


S-201-5


S-201-7.5


S-201-12


S-201-13.5


S-201-15


S-201-24


S-201-27


S-201-48


DC output voltage


5V


7.5V


12V


13.5V


15V


24V


27V


48V


Output voltage error (Note2)


±2%


±2%


±1%


±1%


±1%


±1%


±1%


±1%


Rated output current


40A


26.5A


16.5A


14.7A


13A


8.3A


7.4A


4.2A


Output current range


0-40A


0-26.5A


0-16.5A


0-14.7A


0-13A


0-8.3A


0-7.4A


0-4.2A


Wave and noise(Note3)


150mVp-p


150mVp-p


180mV


180mV


180mV


180mV


240mV


240mV


Inlet stability(Note4)


±0.5%


±0.5%


±0.5%


±0.5%


±0.5%


±0.5%


±0.5%


±0.5%


Load stability(Note5)


±0.5%


±0.5%


±0.5%


±0.5%


±0.5%


±0.5%


±0.5%


±0.5%


DC output power


200W


198.75W


198W


198.45W


198W


199.2W


199.8W


201.6W


Efficiency


74%


79%


80%


80%


81%


83%


83%


84%


Adjustable range for DC voltage


4.5-5.6V


6-9V


10-13.2V


12-15V


13.5-18V


20-26.4V


26-32V


41-56V


AC input voltage range


90~132VAC/186~264VAC SELECTED BY JUMPER OR SWTCH 47~63Hz;254~370VDC


Input current


4.5A/115V 2.5A/230V


AC impulse current


25A/115V 50A/230V


Leakage current


<3.5mA/240VAC


Overload protection


105%150%. TypePULSING HICCUP SHUTDOWN Reset: auto recovery


Over-voltage protection


5.75-6.75V


9.4-10.9V


13.8-16.2V


15.5-18.2V


18-21V


27.6-32.4V


33.7-39.2V


57.6-67.2V


High-temperature protection


RTH3>=90 OUTPUT SHUTDOWN


Temperature coefficient


±0.03%(050)


Setup rise hold up time


200ms,100ms,20ms


Vibration


10500Hz,2G 10min./1cycle,Period for 60min,EACH AXES


Withstand voltage


Input and output interval1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC


Isolation resistance


Input and output interval,Input and enclosure,Output and enclosure500VAC/100M Ohms


Working temperature and humidity


-10+50,20%90%RH


Store temperature and humidity


-20+85,10%95%RH


Overall dimension


215*115*50mm


Weight


0.9Kgs


Safety standards


Design refer to UL 1950


EMC standards


Design refer to FCC Part 15J Conduction Class A

Note:


1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity

2.Error,include the setting error, line stability and load stability.(Note:5)

3.Wave test:adoptingA12double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting

4.Inlet voltage stability test: when is over load, the lowest voltage of inlet representative to the highest voltage.

5.Load stability test: The load is from 0% to 100%,others 60%.

6.C2311must be knocked down.


 

Total0bar [View All]  Related Comments
 
more»Other products

[ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]